Rainwater Reclamation | Rainwater Reclamation System | Rainwater Reclamation Systems
FLUID HANDLING EQUIPMENT SINCE 1970
Call 1-877-PIC-BURT (742-2878)
mfgwebsales@burtprocess.com
Rainwater Reclamation Systems
 

Rainwater Reclamation System Overview

BPE’s Rainwater Reclamation Systems are product of forty years of fluid handling and engineered systems experience. The Rainwater Reclamation System are custom designed to meet your specific requirements for flow and pressure and to maintain water quality to eliminate negative impacts on people and the environment.

Burt Process Equipment’s RainEx line of provides prepackaged solutions for storm rainwater recycling problems. Combining skid mounted tanks, pumps, filtration, sanitization and electrical controls, the RainEx series gives customers a complete treatment package for use in recycled applications such as irrigation, flushing fixtures and cooling tower make-up.

Features of Rainwater Reclamation Systems

Standard Features of Rainwater Reclamation Systems :

  • High quality piping and valves to meet local plumbing codes
  • Prepackaged and factory tested design for reduced installation costs
  • Stainless steel or PVC filtration systems
  • Pigmented storage tanks to minimize bacterial growth
  • Sanitization via ultraviolet or chemical injection for flushing fixture use
  • Touch screen and PLC automatic controls for ease of use
  • Optional dye injection for flushing fixtures
  • On site start-up and training by a factory trained Field Service Technician
  • Optional in-line pH adjustment

The RainEx series offer rainwater recovery system technologies for building upgrades and new construction. Recycled water can be used for flushing fixtures and/or landscape irrigation, providing valuable LEEDs points and aiding in Green Building certification. Utilizing state of the art PLC controls and the latest ultraviolet and chemical sanitants, each skid provides the required water treatment to meet today’s demanding water needs.

RainEx Brochure
Rainex Rainwater Reclaim Questionnaire
Sample O&M Manual
 
RainEX: Your solution to
LEED Certification
RainEX Your solution to LEED Certification

Rainwater Reclamation Sample Systems

Beverage Producer : Direct Storage Rainwater Harvesting Systems


Beverage Producer Direct Storage Style Rainwater Harvesting Systems

The Direct Storage Rainwater Harvesting Systems shall be designed to collect rainwater in an outside storage tank (supplied by others). Water will be re-pressurized from the collection tank to the points of use by (2) sump pumps through the initial strainer filtration to the interior storage tank. Water will then be recirculated in this tank for chlorination and disinfection. The booster pump pack will then pump through bag filters and the water will be injected with dye. When not feeding the points of use, the recirculation pump will recirculate the interior storage tank to keep the water sanitized. The Rainwater Reclamation System shall be controlled via a common PLC driven control panel with touch screen operator interface.   More About Rainwater Harvesting Systems

Pharmaceutical′s : Cistern Storage Rainwater Purification Systems


Pharmaceutical Rainwater Purification Systems

The Cistern Storage Rainwater Purificaxtion Systems include filtration and sanitization equipment and controls to filter 56,000 gallon rainwater cistern. It shall be factory skid-mounted including modularization and pre-plumbing and wiring...   More About Rainwater Purification Systems

High Rise Building′s : Cistern Storage Rainwater Recovery Systems


Rainwater Reclamation Systems High Rise Building′s Cistern Storage Style

The Rainwater Recovery Systems shall be designed to collect rainwater in (2) 30,000 gallon storage tank (supplied by others). Water will be re-pressurized from the collection tank to the points of use by (2) booster pumps. The booster pumps will pump through bag filters and a 254nm UV for sanitization on the Reclamation water skid. When not feeding the points of use, the Rainwater Reclamation Systems pumps will recirculate to the storage tank to keep the water sanitized. Water for flushing fixtures will also be injected with dye. A 55-gallon molded HDPE tank is included with a solenoid driven meter pump...   More About Rainwater Recovery Systems

University : Direct Storage Rainwater Recycling Systems


Rainwater Recycling Systems Direct Storage Style

The Direct Storage Rainwater Recycling Systems for University shall be designed to collect rainwater in a 4,000 gallon storage tank. Collected water will re-pressurized via one of two pumps to output water at a rate of 35 gpm @ 40psi to the irrigation system. When not feeding the irrigation system, one of the pumps shall recirculate the holding tank through a bank of bag filters and a 254 nm UV for sanitization. The Rainwater Reclamation System pumps will automatically alternate with each cycle. The system shall be controlled via a common PLC driven control panel with touch screen operator interface.   More About Rainwater Recycling Systems


Rainwater Reclamation | Rainwater Reclamation System | Rainwater Reclamation Systems
eXTReMe Tracker
@ Burt Process Equipment All Right Reserved, Designed & Developed by Wempro